Furniture fittings catalogue 2019

10.9 www.demos ‑trade.com 220- 240 V 221 6×MINI 1500 mm 1500 mm 150 mm round connector 5,5mm max. 3A total max. 6,25A 355856 36 W, 1,5 A 133 × 42 × 30 355857 60 W, 2,5 A 185 × 64 × 22 360507 100 W, 4,16 A 180 × 66 × 32 355858 150 W, 6,25 A 196 × 99 × 32 6×MINI 1500 mm 1500 mm 150 mm round connector 5,5mm max. 3A total max. 6,25A L I G H T S Strong Plus transformers Observe necessary work rules for sensitive electronics, for detailed information see p. 10.5 • series of transformers with high-quality components and extended warranty (5 years) • for power supply of LED strips and lights with 24 V voltage, direct current • power supply 220-240 V, 50 Hz • output cable with a circular connector + Mini distributor with 6 outputs for easy connec- tion of LED strips and accessories • maximum load on one output of the 3 A distributor • covered terminal box for direct connection of the outlet and inlet (direct connection should be carried out by a competent person) • in order to achieve optimal function, it is recommended to have the transformer as close to the light source as possible (Longer cables cause voltage losses and a subsequent drop in luminous intensity. They may also have disturbing influence on near electrical appliances.) • power of the transformer must be higher than the input power of the lights, recommen- ded reserve 20%, for continuous lighting the reserve should be increased to 30% • the transformer should have a minimum distance 0.5 m from other electrical appliances • place in such a way that sufficient ventilation – heat dissipation – is provided • cable length 2 m • CE certificate Transformers It is not possible to combine 12 V LED strips with the 24 V transformer and vice versa. The transformer must always have sufficient reserve for the respective LED strip set. During normal use, the reserve should be 20%, if used for more than 5 hours, we recommend increasing the reserve to 30% or more. Offered transformers have protection to prevent damage, at overloading the transformer switches off and after reducing the load and cooling, the transformer is functional again. However, overloading has a negative impact on the overall service life. The transformer should be installed so that it can be accessed and possibly replaced at any time and it should be well ventilated. Installation in small, unventilated space reduces its service life. Please note that the supply voltage must comply with ČSN EN 60038, damage due to over-voltage in the electrical network is not a reason for placing a complaint. Complaints are solved by replacing the faulty transformer. Other costs with replacing the connection are not recognised. connection diagram of LED strips to the transformer code power L × D × H (mm) Strong Plus – transformers Transformer power (W) = x + 20% (30%) x = LED strip length (m) × LED strip power input (W/m) Example: When using a strip with 14.4W/m and length of 2.5 m, the power of the strip is 36W + 20% reserve (7.2 W) = 43.2 W. You will thus need a 60 W transformer. years Warranty CONTENTS

RkJQdWJsaXNoZXIy MzEyMDA=